无码视频在线,东京热一区二区三区无码,精品热线九九精品视频,精品国产综合成人亚洲区2022,国产精品久久久久蜜芽,亚洲va国产日韩欧美精品,台湾亚洲自偷自拍另类12p

News
Your location:Home > News > Company News

Causes of inaccurate line selection of small current grounding line selection device

AddTime:2021-01-14 16:22:15   Views:     【 Big Mid Small 】   Print   Close

In the substation, the main function of small current grounding line selection device is to select the line accurately. For example: in coal mining enterprises, with the development of mine production, many local substations have been re planned, transformed and so on, which have brought certain pressure to the operation of small current grounding line selection device.

The traditional small current grounding line selection device adopts single line selection principle, and its own accuracy performance is poor, so it is difficult to get good results in line selection work. Some substations have undergone many times of capacity expansion and transformation. The zero sequence current transformer of the new line is inconsistent with the zero sequence current transformer model and transformation ratio of the original other lines. The zero sequence current of the grounding line collected may be smaller than that of the ungrounded line, which will directly cause the wrong selection of the line.

When some substations expand their capacity, arc suppression coils are added to the bus bar in the substation, which makes the capacitive grounding current compensated by the inductive current, and the small current grounding system based on the principle of amplitude and phase comparison of zero sequence current can not be effectively distinguished.

After the circuit transformation, the parallel cable does not pass through the zero sequence current transformer, which makes the zero sequence current monitored too small and leads to the wrong identification of the device. The polarity of zero sequence current transformer in a few circuits was wrongly connected during construction.

In the application process of small current grounding line selection, it has brought a lot of positive effects, but it also needs to take preventive measures. The small current grounding line selection device on the market can not achieve 100% line selection accuracy, so it can better integrate with the substation, and it can deal with different situations more quickly.


Prev:Practical application of power quality online monitoring system  Next:Requirements of building power quality online monitoring system
Back To Top
Copyright ? Bao Ding Shi Simaier Electric Co., Ltd. All Rights Reserved  
  • <strike id="0eits"></strike>
    <track id="0eits"><strike id="0eits"><thead id="0eits"></thead></strike></track>
      <i id="0eits"></i>
    • <i id="0eits"><legend id="0eits"></legend></i>
        1. <abbr id="0eits"></abbr>

        无码视频在线,东京热一区二区三区无码,精品热线九九精品视频,精品国产综合成人亚洲区2022,国产精品久久久久蜜芽,亚洲va国产日韩欧美精品,台湾亚洲自偷自拍另类12p 免费看无码大黄网站 亚洲中文无码亚洲人成频 午夜尤物禁止18点击进入 久久黄色视频导航 欧美精品九九99久久在观看